Analysis of Core Chemical Composition
This is the primary basis for determining purity; high-purity quartz glass requires an SiO₂ content of ≥99.9%, while semiconductor-grade glass requires ≥99.999%. Equipment such as X-ray fluorescence (XRF) and inductively coupled plasma mass spectrometry (ICP-MS) can be used to precisely measure the levels of impurity elements like Al, Fe, Na, and K. Total metal impurity content must be below 10 ppm for optical-grade products and below 1 ppm for semiconductor-grade products.
Assessment via Optical Performance
Higher-purity quartz glass exhibits superior light transmission across the entire ultraviolet (UV) to near-infrared (NIR) spectrum. For a qualified high-purity product with a thickness of 2 mm, UV transmittance at 200 nm exceeds 85%, with no dark absorption zones caused by significant impurities. Lower-purity products often show a sharp drop in UV transmittance and significant internal scattering; additionally, infrared spectroscopy can be used to measure hydroxyl (OH) content, with qualified low-hydroxyl products requiring a content of <5 ppm.
Verification Against Physical Parameters
High-purity quartz glass has a standard density of 2.2 g/cm³, a stable refractive index of 1.458 ± 0.003, a thermal expansion coefficient of 0.55 × 10⁻⁶/K, and a hardness of ≥6.5. Significant deviations between measured values and these standards indicate a high impurity content and failure to meet purity requirements.
Inspection of Appearance and Defects
High-purity quartz glass is free of visible internal bubbles, striae, or inclusions. Laser scattering analysis should show internal bubble diameters of <0.1 mm and a distribution density of ≤3 bubbles/cm³. Lower-purity products often contain numerous visible impurity specks and opaque, flocculent regions, directly indicating insufficient raw material purification.